B). ACCESSORIES/FEATURES PROVIDED AS STANDARD IN EACH ACB (AR/AT-SERIES) |
|
|
|
|
|
|
|
|
1 |
STANDARD TRIP TYPE: |
True RMS Sensing + Selectivity. |
|
2 |
PROTECTIONS: |
|
LSIG |
|
|
3 |
AUXILIARY SWITCHES: |
4C (AR Types). |
|
|
4 |
TRIP INDICATIONS/SWITCHES: |
The associated LED is lit to indicate which trip function, LTD, STD/INST |
|
|
|
or PTA ALARM CONTACTS: has operated. Also voltage-free contacts |
|
|
|
on Trip Device operate simultaneously. PTA Indication & Alarm Switch. |
|
|
5 |
PRE-TRIP ALARM: |
|
|
|
|
|
|
Adj. PTA for Load Control |
|
|
6 |
PAD LOCKING: |
|
Provision for Pad Locking the ACB in OPEN position is provided. |
7 |
BUILT-IN TESTER: |
|
TEMPOWER ACBs can be tested in the field anytime for precise |
|
|
|
operation with built-in tester. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C). OPTIONAL ACCESSORIES & TRIPPING DEVICES: |
|
|
|
|
|
|
|
|
|
|
· |
Trip Indicator Switch |
|
|
|
|
|
|
|
|
|
|
· |
Close-Open cycle Counter |
|
|
|
|
|
|
|
|
|
· |
Key Interlock |
|
|
|
|
|
|
|
|
|
|
· |
Key Interlock System |
|
|
|
|
|
|
|
|
|
· |
Mechanical Interlock (between 2 ACBs) |
|
|
|
|
|
|
|
|
|
· |
Mechanical Interlock (between 3 ACBs) |
|
|
|
|
|
|
|
|
|
· |
Add for Adjustable Earth Fault Protection Relay (w/o 4th CT) for 3Pole ACB… |
|
|
Add for Adjustable Earth Fault Protection Relay (w/built-in 4th CT) for 4Pole ACB |
|
|
|
|
|
|
|
· |
Add for Aux CT for enabling EF Protection |
|
|
|
|
|
|
|
|
|
· |
Under-Voltage Trip (Time Delay Type): with remote trip option, Selectable Voltages. |
|
|
|
|
|
|
|
· |
Shunt trip |
|
|
|
|
|
|
|
|
|
|
· |
Motor Mechanism for Spring Charging |
|
|
|
|
|
|
|
|
|
· |
Add for Aux. Switches 7C instead of standard 4C |
|
|
|
|
|
|
|
|
· |
Add for Aux. Switches 10C instead of standard 4C |
|
|
|
|
|
|
|
|
· |
Spring Charge Indication Switch |
|
|
|
|
|
|
|
|
|
· |
Drawout ACBs with cradle |
|
|
|
|
|
|
|
|
|
· |
Safety Shutters for Drawout cradle |
|
|
|
|
|
|
|
|
|
· |
Closing Operations: Motor charging or solenoid operation |
|
|
|
|
|
|
|
|
· |
Closing Latch Release (CLR) for Remote ON for charged ACB(for manual/motorized) |
|
|
|
|
|
|
|
· |
Spare OCR for "AT/AR" Series |
|
|
|
|
|
|
|
|
|
· |
IP55 Cover (for mounting on switchboard door to provide IP55 deg. of protection |
|
|
|
|
|
|
|
· |
Door Flange (Covers the panel cut-out on the switchboard) |
|
|
|
|
|
|
|
|
· |
Digital Remote Monitor for ACBs |
|
|
|
|
|
|
|
|
|
· |
Communication Interface Unit for AR Series |
|
|
|
|
|
|
|
|
· |
Contact Temperature Monitoring Function |
|
|
|
|
|
|
|
|
Note: GFT: For 3P ACB use a standard -/5A CT for the Neutral pole. Also please use additional Aux CT for 3P / |
|
4P ACB for EF/GF protection. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TERASAKI TemPower2 ACBs are based on True R.M.S. Sensing + Selectivity. |
|
|
Hence they are designed for use as Main Incoming Breaker as well as a Secondary Breaker. |
|
|
|
|
|
|
|
|
TERASAKI TemPower2 ACBs are custom designed. |
|
|
|
Your individual specifications can be incorporated by the factory. For 4-POLE and Drawout ACBs AND |
|
FURTHER DETAILS, PLEASE CONTACT US. |
|
|
|
|
|
|
|
|
|
|
NOTE: |
|
|
|
|
|
This list is subject to change without notice and goods being in stock. The prices in the list are reference prices and not sale prices. |
|
Discounts/Multipliers are applicable. The delivery, packing and forwarding charges are extra. |
|
|
All dispatches are made on buyer’s risk and account. |
|
|
|
|